FlexiTacDocs
On this pageOverview

Fabricate a sensor

Turn two FPCs, a piece of Velostat and some tape into a working FlexiTac-V2 sensor in under three minutes.

Fabricating a FlexiTac-V2 sensor is mostly lamination: no soldering, and no special tools beyond scissors or a craft knife. Once you have done it once, a sensor takes under three minutes.

Materials

Workspace with the two FPCs, lamination sheets, Velostat and a roll of polyimide tape
Everything for one sensor: the top and bottom FPCs, adhesive lamination sheets, Velostat and polyimide tape.
ItemBOM #Notes
Top FPC and bottom FPC1One of each per sensor
Adhesive laminating sheets4Two pre-cut pieces, one per FPC
Velostat / Linqstat3One piece that covers the electrode area
Polyimide tape2For sealing the edges
FFC extenders (16- and 32-pin) and flat cables7–12For connecting to the reading board in step 4
Assembled reading board5–6Flashed or not; you can flash it later

See Order parts for the full bill of materials.

How the layers stack

A FlexiTac sensor is five thin layers. Both FPCs turn their copper electrodes toward the Velostat in the middle: the top FPC's 12 columns face down and the bottom FPC's 32 rows face up. Wherever a row crosses a column there is a taxel, and pressing it squeezes the film between the two electrodes.

Exploded view of a FlexiTac-V2 sensor. From top to bottom: a clear laminating sheet, the top FPC seen from its back with 12 column electrodes, the black Velostat film, the bottom FPC with 32 row electrodes facing up, and a second laminating sheet. Both FPC tails run out to the same side. 1 2 3 4 5
  1. Laminating sheet holds the top FPC from behind.
  2. Top FPC: 12 column electrodes, copper side down. You see its back here, with the copper showing through.
  3. Velostat: the pressure-sensitive film, cut to cover the electrode area.
  4. Bottom FPC: 32 row electrodes, copper side up.
  5. Laminating sheet holds the bottom FPC from behind.

Steps 1 and 2 below build exactly this stack: each FPC on its own laminating sheet, then the Velostat between them. Both tails leave on the same side. Step 3 then seals the edges with polyimide tape.

Build the sensor

  1. Attach each FPC to a lamination sheet and align it

    Peel a pre-cut lamination sheet and attach the top FPC to it. Do the same with the bottom FPC on a second sheet. Align the corners exactly, as in the photos: the two layers must line up when you stack them in step 2.

    Peeling the backing from a lamination sheet
    Peel the lamination sheet.
    Placing the FPC onto the adhesive sheet
    Place the FPC, corners aligned.
    An FPC laminated onto its sheet, held up to the camera
    One laminated FPC layer.
  2. Stack the Velostat between the two layers

    Place the Velostat in the middle, between the two prepared layers, centered over the electrode area. Close the stack with the second layer. Once it's centered, the sensor stack already works.

    Placing a black Velostat sheet over a laminated FPC
    Center the Velostat over the electrodes.
    Closing the sensor stack with the second FPC layer
    Close the stack with the other layer.
  3. Seal the edges with polyimide tape

    Lay out a strip of polyimide tape and seal the border of the stack. This doesn't change how the sensor works. It holds the layers in place and keeps the sensor intact through long experiments.

    Placing the sensor stack on a strip of polyimide tape
    Place the stack on the tape.
    Folding the polyimide tape around the sensor edges
    Fold the tape around the edges.
  4. Connect to the reading board

    Insert each sensor's gold fingers into an FFC connector (extender), then run a flat flexible cable from each connector to the reading board. The wider gold-finger end takes the 32-pin connector and cable, and the narrower one takes the 16-pin connector and cable.

    The sealed sensor with the reading board, two flat flexible cables and FFC connectors
    Sealed sensor, reading board, flat cables and connectors.
    Inserting the FPC gold fingers into a connector
    Insert the gold fingers into the connector.
    Attaching a flat flexible cable to the connector
    Attach the flat cable.
    Finished sensor connected through two flat cables to the reading board
    Done: the sensor is connected to the reading board.

Tips for a good sensor

  • Fully seat the gold fingers. Push each FPC end all the way into its connector, straight and not skewed. A finger that's half-seated or off by one pin is the most common cause of dead or swapped rows.
  • Mind the cable orientation. FFC contacts are on one side only. If a whole sensor reads nothing, check that each cable's contacts face the connector contacts at both ends.
  • The Adafruit extenders need practice. They're compact but take careful alignment. The AliExpress extenders (BOM #12) are bulkier but easier to install.
  • Keep the Velostat covering every crossing. Taxels outside the film won't respond. An off-center film shows up as a dead edge on the heatmap.
  • Make a few at once. Sensors are consistent enough that spares are interchangeable, and having one makes it easy to tell a bad sensor from a bad board.

Next